Skip to main content
Distribution Boards

Distribution Boards — Surface Mounting

ABS distribution boards mounted on the wall surface. From 2 to 42 modules; metal key and terminal bar included for the DT39XX range. Distribution Boards — Surface Mounting is listed with 49 reference codes.

Distribution Boards — Surface Mounting
Reference codes
49
Protection
IP40 – IP65
Body
ABS · thermoplastic
Flammability
UL94 V0 / V2
01

Dimension and reference code table

You can paste the code straight into the quote form. Use the box below to search within the table.

ImageProduct codeModulesPack
Distribution Boards - Surface Mounting, 8 Modules - DT 30908 B
DT 30908 B8 Modules20
Distribution Boards - Surface Mounting, 12 Modules - DT 30912 B
DT 30912 B12 Modules12
Distribution Boards - Surface Mounting, 24 (12x2) Modules - DT 30924 B
DT 30924 B24 (12x2) Modules10
Distribution Boards - Surface Mounting, 36 (12x3) Modules - DT 30936 B
DT 30936 B36 (12x3) Modules10
Distribution Boards - Surface Mounting, 36 (18x2) Modules - DT 30936-1 B
DT 30936-1 B36 (18x2) Modules10
Distribution Boards - Surface Mounting, 54 (18x3) Modules - DT 30954 B
DT 30954 B54 (18x3) Modules4
Distribution Boards - Surface Mounting, 72 (18x4) Modules - DT 30972 B
DT 30972 B72 (18x4) Modules4
Distribution Boards - Surface Mounting, 8 Modules - DT 32908 B
DT 32908 B8 Modules20
Distribution Boards - Surface Mounting, 12 Modules - DT 32912 B
DT 32912 B12 Modules12
Distribution Boards - Surface Mounting, 24 (12x2) Modules - DT 32924 B
DT 32924 B24 (12x2) Modules10
Distribution Boards - Surface Mounting, 36 (12x3) Modules - DT 32936 B
DT 32936 B36 (12x3) Modules10
Distribution Boards - Surface Mounting, 36 (18x2) Modules - DT 32936-1 B
DT 32936-1 B36 (18x2) Modules10
Distribution Boards - Surface Mounting, 54 (18x3) Modules - DT 32954 B
DT 32954 B54 (18x3) Modules4
Distribution Boards - Surface Mounting, 72 (18x4) Modules - DT 32972 B
DT 32972 B72 (18x4) Modules4
Distribution Boards - Surface Mounting, 5 Modules - DT 11905
DT 119055 Modules24
Distribution Boards - Surface Mounting, 8 Modules - DT 11908
DT 119088 Modules24
Distribution Boards - Surface Mounting, 12 Modules - DT 11912
DT 1191212 Modules12
Distribution Boards - Surface Mounting, 24 Modules - DT 11924
DT 1192424 Modules12
Distribution Boards - Surface Mounting, 36 Modules - DT 11936
DT 1193636 Modules10
Distribution Boards - Surface Mounting, 5 Modules - DT 1905
DT 19055 Modules24
Distribution Boards - Surface Mounting, 8 Modules - DT 1908
DT 19088 Modules24
Distribution Boards - Surface Mounting, 12 Modules - DT 1912
DT 191212 Modules12
Distribution Boards - Surface Mounting, 24 Modules - DT 1924
DT 192424 Modules12
Distribution Boards - Surface Mounting, 36 Modules - DT 1936
DT 193636 Modules10
Distribution Boards - Surface Mounting, 1 Module - DT 01011
DT 010111 Module140
Distribution Boards - Surface Mounting, 2 Modules - DT 01012
DT 010122 Modules100
Distribution Boards - Surface Mounting, 4 Modules - DT 01034
DT 010344 Modules56
Distribution Boards - Surface Mounting, 8 Modules - DT 01035
DT 010358 Modules28
Distribution Boards - Surface Mounting, 2 Modules - DT 3902
DT 39022 Modules30
Distribution Boards - Surface Mounting, 4 Modules - DT 3904
DT 39044 Modules17
Distribution Boards - Surface Mounting, 8 Modules - DT 3908
DT 39088 Modules9
Distribution Boards - Surface Mounting, 12 Modules - DT 3912
DT 391212 Modules7
Distribution Boards - Surface Mounting, 26(13x2) Modules - DT 3926
DT 392626(13x2) Modules5
Distribution Boards - Surface Mounting, 42(14x3) Modules - DT 3942
DT 394242(14x3) Modules4
Distribution Boards - Surface Mounting, Metal Key for DT39XX range modules - DT 3900
DT 3900Metal Key for DT39XX range1
Distribution Boards - Surface Mounting, Terminal Bar for DT39XX range modules - DT 3901
DT 3901Terminal Bar for DT39XX range1
Distribution Boards - Surface Mounting, 5 Modules - DT 20905
DT 209055 Modules14
Distribution Boards - Surface Mounting, 8 Modules - DT 20908
DT 209088 Modules12
Distribution Boards - Surface Mounting, 12 Modules - DT 20912
DT 2091212 Modules10
Distribution Boards - Surface Mounting, 24 (12x2) Modules - DT 20924
DT 2092424 (12x2) Modules4
Distribution Boards - Surface Mounting, 36 (12x3) Modules - DT 20936
DT 2093636 (12x3) Modules3
Distribution Boards - Surface Mounting, 54 (18x3) Modules - DT 20954
DT 2095454 (18x3) Modules2
Distribution Boards - Surface Mounting, 72 (18x4) Modules - DT 20972
DT 2097272 (18x4) Modules2
Distribution Boards - Surface Mounting, Metal Key for DT 209XX range modules - DT 20900
DT 20900Metal Key for DT 209XX range1
Distribution Boards - Surface Mounting, 1x5M - Suitable for DT 20905 modules - DT 913
DT 9131x5M - Suitable for DT 2090510
Distribution Boards - Surface Mounting, 1x12M - Suitable for DT 20912 modules - DT 914
DT 9141x12M - Suitable for DT 209124
Distribution Boards - Surface Mounting, 2x8M - Suitable for DT 20908 modules - DT 915
DT 9152x8M - Suitable for DT 209083
Distribution Boards - Surface Mounting - DT 904
DT 9042x12M - Suitable for DT 20912–DT 20924–DT 209362
Distribution Boards - Surface Mounting, 2x19M - Suitable for DT 20954 - DT 20972 modules - DT 12012
DT 120122x19M - Suitable for DT 20954 – DT 209722
02

Distribution Boards — Surface Mounting — technical overview

What surface-mounting distribution boards are for

Demte surface-mounting distribution boards are wall-mounted enclosures for modular protection devices on DIN rail, for walls where the board cannot be recessed. Four series cover 1 to 72 modules: IP40 boards in Toner Black and in soft white polycarbonate, and IP65 boards in two series, with IP ratings to EN 60529.

Choosing the series

  • Toner Black series, IP40: 8 to 72 modules with a smoked transparent door (DT 309) or blank door (DT 329), in rows of 12 or 18 modules.
  • Benefit series, IP40: 5 to 36 modules, surface (DT 119) or flush (DT 19) versions, plus covered boards from 1 to 8 modules (DT 010).
  • DT 39 series, IP65: 2 to 42 modules with a smoked transparent door, up to 42 (14 × 3) modules.
  • DT 209 series, IP65: 5 to 72 modules with a smoked transparent door, in RAL 7035 grey.

Construction and features

Toner Black series

  • Hinged door that opens more than 180°.
  • Ergonomic opening and closing system.
  • Ready to install the terminal blocks for neutral and earth connection.
  • Operating temperature range of -25 to +60 °C.

Benefit series

  • Polycarbonate raw material, impact resistant, soft white.
  • Resistant to chemical and weathering agents.
  • Terminal block included; door opens more than 90°.

IP65 series

  • DT 39 series: pre-drilled entries, wide space for cabling, 1/4 turn screws and fast installation.
  • DT 209 series: certificate TS 3033 EN 60529 (IP test), operating temperature -25 to +60 °C.

Accessories and packing

  • Metal keys: DT 3900 for the DT 39 series, DT 20900 for the DT 209 series.
  • Terminal bar DT 3901 for the DT 39 series.
  • Terminal items for the DT 209 series: DT 913, DT 914, DT 915, DT 904 and DT 12012, each matched to specific board sizes.
  • Pack quantities fall as size grows, for example from 20 pcs for 8-module Toner Black boards to 2 pcs for 72-module DT 209 boards.

Frequently asked questions

Which surface board should I choose for a damp location?

Choose one of the IP65 series. The DT 39 series covers 2 to 42 modules with pre-drilled entries and 1/4 turn screws; the DT 209 series covers 5 to 72 modules in RAL 7035 grey and carries a TS 3033 EN 60529 IP test certificate.

Is a terminal block included?

In the Benefit series the terminal block is included. Toner Black boards are ready to install neutral and earth terminal blocks. For the IP65 series, terminal bar DT 3901 and terminal items such as DT 913 and DT 904 are ordered separately.

What is the Benefit series?

Benefit is a polycarbonate series in soft white with IP40 protection, offered as surface boards DT 119 and flush boards DT 19 from 5 to 36 modules, plus covered versions from 1 to 8 modules. It is impact resistant and resistant to chemical and weathering agents.

03

Catalogue

Distribution Boards — Surface Mounting is listed in the catalogues below. Download the PDF for full dimensions, drawings and technical data.

Next step

Request a quote for this product.

Send the code, dimensions and quantity; we will reply with price and lead time.

Last updated: